Worked example 01 · AISC 360-22

Steel Beam Design Example
AISC 360-22 LRFD & ASD

Follow the LRFD bending, shear and deflection checks for a 30 ft W21×44, then compare the ASD strength checks for the same beam. Open the model to run an LRFD or ASD check in Design.

Free PDF · Full input model · LRFD + ASD comparison

THE DESIGN BRIEFW21×44 / A992
Actual Optimal Beam model: 30 ft simply supported W21X44 with 0.5 kip/ft dead load, 1 kip/ft live load and 0.044 kip/ft self-weight
30 ftPin–roller span
50 ksiYield strength
44 lb/ftSection weight
Actual calculator model. Continuous compression-flange bracing is assumed; it is not drawn in this 1D view.
Bending70.8% used
Shear15.5% used
Total deflection76.7% used
Live deflection74.5% used

Total deflection governs. All four selected checks pass for the stated assumptions.

01 / The problem

A steel floor beam with a clear design basis.

Check a uniform W21×44 ASTM A992 beam spanning 30 ft between an ideal pin and roller. It carries a full-span superimposed dead load of 0.5 kip/ft and live load of 1 kip/ft. Include the beam’s own weight, assume continuous compression-flange bracing, and use AISC 360-22 LRFD for strength.

This is a steel beam design example for a defined gravity-load case. A passing member check is one part of a complete structural design.

W21×44 properties used in this calculation

dOverall depth
20.70 in
bfFlange width
6.50 in
twWeb thickness
0.350 in
tfFlange thickness
0.450 in
kdesDesign fillet distance
0.95 in
ACross-sectional area
13.0 in²
IxMajor-axis inertia
843 in⁴
SxElastic section modulus
81.6 in³
ZxPlastic section modulus
95.4 in³
ryMinor-axis radius
1.26 in
EElastic modulus
29,000 ksi
FyYield strength
50 ksi
W21X44 I-section: 20.7 inch depth and 6.5 inch flange width; schematic with simplified filletsbf = 6.50 ind = 20.70 intw = 0.350tf = 0.450W21×44
Schematic, simplified fillets.
Explore the section properties ↗
Restraint is a design input. The supporting system is assumed to prevent compression-flange lateral movement and provide required torsional restraint. Bracing strength, stiffness, attachments and construction-stage stability must be designed separately. No composite slab contribution is included.

02 / Calculation

Build the loads and combinations

Keep member self-weight in the dead load case. The entered 0.500 kip/ft dead load excludes the beam itself, so add the W21X44 weight once.

Self-weight = 44 / 1,000 = 0.044 kip/ft
D = 0.500 + 0.044 = 0.544 kip/ft
L = 1.000 kip/ft
1.4D = 1.4(0.544) = 0.7616 kip/ft
1.2D + 1.6L = 1.2(0.544) + 1.6(1.000) = 2.2528 kip/ft
Service D + L = 0.544 + 1.000 = 1.544 kip/ft

These are the selected gravity-only combinations for this teaching example. Establish the applicable building code and load standard, and include every required load, combination and pattern for an actual project. AISC 360 is the member-strength specification; it does not make this a complete project load assessment.

Load scenario results for the W21×44
Scenariow (kip/ft)Each reaction (kip)Max. moment (kip-ft)
1.4D0.761611.42485.68
1.2D + 1.6L2.252833.792253.44
D + L1.54423.16173.7
Live only115112.5

03 / Calculation

Calculate reactions, shear and moment

The full-span UDL and symmetric pin-roller supports give equal reactions. Use the governing factored load for LRFD strength; use unfactored service loads for deflection.

RA = RB = wu L / 2 = 2.2528(30) / 2 = 33.792 kip
|Vu|max = 33.792 kip, at the supports
V(x) = 33.792 - 2.2528x [kip; x in ft]
M(x) = 33.792x - 1.1264x2 [kip-ft; x in ft]
V(x) = 0 at x = 15 ft
Mu = wu L2 / 8 = 2.2528(302) / 8 = 253.44 kip-ft

Sagging moment is positive. The shear changes sign at midspan, where moment reaches its maximum. The ideal supports carry no end moment. The reaction is a demand on the support connection, not a completed connection or bearing check.

04 / Calculation

Check steel beam bending strength

First establish that the flange and web are compact. This rolled, doubly symmetric W shape is checked about its major axis, with continuous restraint of the compression flange and the required torsional restraint assumed.

Flange: bf / (2tf) = 6.50 / (2 x 0.450) = 7.222
Flange compact limit = 0.38 sqrt(E/Fy) = 0.38 sqrt(29,000/50) = 9.152 > 7.222
Clear web height h = d - 2kdes = 20.70 - 2(0.95) = 18.8 in
Web: h / tw = 18.80 / 0.350 = 53.714
Web compact limit = 3.76 sqrt(E/Fy) = 90.553 > 53.714
Mn = Mp = Fy Zx = 50(95.4) = 4,770 kip-in = 397.5 kip-ft
φb Mn = 0.90(397.50) = 357.75 kip-ft
Bending utilization = 253.44 / 357.75 = 70.8% < 100%

AISC Table B4.1b (Cases 10 and 15), Sections F1 and F2, Eq. F2-1. Compactness permits plastic strength. Continuous bracing removes a finite unbraced segment from this example; LTB does not govern. For context, Lp = 1.76 ry sqrt(E/Fy) = 53.41 in. If restraint changes, evaluate the actual unbraced lengths and the applicable F2 lateral-torsional buckling provisions. Do not use the 30 ft span as proof of adequate bracing.

05 / Calculation

Check web shear strength

For this rolled W shape, the web slenderness falls just below the G2.1(a) limit. Use the applicable rolled-section shear factors, rather than automatically using the bending resistance factor.

h / tw = 53.714 <= 2.24 sqrt(29,000/50) = 53.946
Cv1 = 1.0; φv = 1.0
Aw = d tw = 20.70(0.350) = 7.245 in2
Vn = 0.6 Fy Aw Cv1 = 0.6(50)(7.245)(1.0) = 217.35 kip
φv Vn = 1.0(217.35) = 217.35 kip
Shear utilization = 33.792 / 217.35 = 15.5% < 100%

AISC G2.1(a), Eqs. G2-1 and G2-2. The shear area is the overall depth d times web thickness tw; the clear height h is used for slenderness. The rolled-section factor criterion is checked with unrounded values. Bearing and web crippling at the supports remain separate checks.

06 / Calculation

Check total and live-load deflection

Use consistent inch-kip units in the elastic beam equation. These project limits are L/240 for total service load and L/360 for live load; they are chosen criteria for this example, not universal AISC limits.

Span = 30 x 12 = 360 in; E = 29,000 kip/in2; Ix = 843 in4
δmax = 5w L4 / (384 E Ix)
Total w = 1.544 / 12 = 0.12866667 kip/in
δtotal = 5(1.544/12)(3604) / [384(29,000)(843)] = 1.15104 in
Total limit = 360 / 240 = 1.5 in; utilization = 76.7%
δlive = 5(1.000/12)(3604) / [384(29,000)(843)] = 0.74549 in
Live limit = 360 / 360 = 1 in; utilization = 74.5%

Both maximum deflections occur at midspan. This is linear-elastic, small-displacement Euler-Bernoulli bending without shear deformation, composite stiffness or camber subtraction. Floor vibration and finishes-sensitive serviceability criteria are outside this example.

The governing check1.151 in of a 1.500 in limit

Total service deflection uses 76.7% of the allowed movement. This is more critical than the 70.8% bending utilization for this model.

07 / Alternative design method

What changes with ASD?

The same nominal section strengths can also be checked using ASD. Use the selected D + L strength combination here, not the LRFD-factored load.

Ma = (D + L) L2 / 8 = 1.544(302) / 8 = 173.7 kip-ft
Mn / Ωb = 397.50 / 1.67 = 238.024 kip-ft
ASD bending utilization = 173.70 / 238.024 = 73%
Va = 1.544(30) / 2 = 23.16 kip
Vn / Ωv = 217.35 / 1.50 = 144.9 kip
ASD shear utilization = 23.16 / 144.90 = 16%

AISC F1 and G2.1(a). The total and live deflection checks stay the same. LRFD and ASD are separate design methods; do not mix factored demands with ASD available strengths. The downloadable model includes the D + L ASD assignment.

08 / Steel beam sizing

Lighter or shallower? Compare the tradeoff.

W21×44 is the lightest of these three passing alternatives. W18×46 and W16×50 reduce depth, but weigh more and use more of the deflection allowance. Recalculate self-weight for every candidate: the total dead loads become 0.544, 0.546 and 0.550 kip/ft respectively.

Same span, loads, grade, continuous bracing and project limits; LRFD
SectionWeight
(lb/ft)
Depth
(in)
BendingShearTotal δLive δ
W21X444420.770.8%15.5%76.7%74.5%
W18X464618.174.6%17.3%91.0%88.3%
W16X505016.373.7%18.2%98.5%95.4%

Percentages are demand / available strength or project deflection limit. All values are calculated with each candidate’s own properties and self-weight. This comparison is not a universal span table or a claim that every project should use the lightest section.

Actual product comparison of passing W21X44, W18X46 and W16X50 sections
The same alternatives in Optimal Beam’s section comparison.

09 / Reproduce the result

Open the inputs. Follow the calculation.

The loadable model includes the span, supports, W21×44 catalog section, named dead/live cases, combinations, automatic self-weight and example design assumptions. It opens in a new tab so you can keep this guide beside the calculator.

  1. Review Beam Input. Confirm 30 ft, the two distributed loads and automatic self-weight in the Dead case. The initial analysis view is service D + L.
  2. Run the analysis. For service D + L, expect 23.16 kip reactions and 173.70 kip-ft peak moment. Select LRFD 1.2D + 1.6L to see 33.792 kip and 253.44 kip-ft.
  3. Open Design and check the current section. Review A992, LRFD, continuous bracing, L/240 total and L/360 live. Compare the four utilization values with the summary above.
  4. Compare ASD. Change Method to ASD and check the current section again. Compare bending and shear with the ASD calculations above. The service deflection checks use the same limits.
  5. Try a depth constraint. Use Find sections, limit maximum depth, compare candidates and apply one. Then review the recalculated loads and checks.

The example PDF is free to download. Exporting your own live calculation reports follows your account plan. Changes to loads, span, section or restraint require a fresh check.

10 / Scope & references

Understand what this example establishes.

W21×44 passes the selected bending, shear, total deflection and live deflection checks for this model. The example does not establish connection design, support bearing or web crippling, bracing adequacy, vibration, fatigue, fire resistance, axial interaction, torsion, composite action or construction-stage stability.

Loads, combinations and serviceability criteria must match the actual project. This educational calculation is not a construction design or an independent engineering approval.

Review the product’s AISC verification evidence and scope ↗

  1. AISC 360-22 Specification for Structural Steel Buildings ↗

    Table B4.1b, F1, F2, G2 and Appendix 6 for restraint design. Consult applicable errata.

  2. W21X44 catalog dimensions and properties ↗

    AISC Shapes Database v16.0. US customary properties are used throughout; displayed metric values are not mixed into the calculations.

  3. University of Illinois Shi Lab: direct F2 worked check ↗

    Independent reproduction of AISC Companion F.1-1B; methodological reference for compact, continuously braced W-shape flexure. It uses a different beam.

  4. University of Illinois Shi Lab: direct G2 worked check ↗

    Independent reproduction of AISC Companion G.1B; methodological reference for rolled-section shear factors. It uses a different beam.