AISC 360-22 · US steel sections
Steel Beam Size Calculator for Span, Load & Deflection
Size and compare steel sections for free. Find the lightest steel I-beam, channel, HSS or pipe that passes bending, shear and deflection checks for your span and loads.
Beam condition
Custom supports, loads or combinations? Open Beam Calculator ↗
Worked example · three checked sections
W21×44
Passes selected checksThe lightest of these three alternatives. Search to find all passing W-shapes for your inputs.
| Section | Depth, in | Weight, lb/ft | Total deflection |
|---|---|---|---|
| W21X44 | 20.70 | 44 | 76.7% |
| W18X46 | 18.10 | 46 | 91.0% |
| W16X50 | 16.30 | 50 | 98.5% |
Free sizing, section comparisons and beam diagrams.
Service diagrams Shear · Moment · Deflection
Member bending, shear and service deflection for the stated model. Connections, bearing, bracing adequacy and floor vibration need separate checks. See design basis.
From span and loads to a steel section
How to size a steel I-beam
A steel beam size must satisfy strength and deflection, fit the available depth and have the assumed flange restraint. Choose a section family, then search its AISC shapes by span, dead load and live load. Passing sections appear in order of weight.
- Define the span and loading. Choose the section family and support condition, enter the labeled span or total length, and enter unfactored dead and live loads. Use line loads, or area loads multiplied by tributary width.
- Choose LRFD or ASD. The calculator applies the displayed gravity combinations automatically. Review flange bracing, the steel grade and both deflection limits.
- Calculate and compare sizes. Check all four utilization ratios, then compare actual depth and weight. A nominal W18 designation does not guarantee an 18-inch clearance.
- Continue with the selected section. Open it in the beam calculator to retain the exact model, add loads or supports, save your work and develop the design.
Which tool fits your task? Use this page to find a size for one of the five standard support conditions with uniform loading over the whole member. Use the W-beam size chart to look up dimensions, or the full calculator to check a known section, point loads, unequal spans or custom supports.
Simply supported, cantilever and continuous steel beams
Choose the condition that matches the actual structure. The same span and load can produce very different bending moments and deflections when the supports change. The selector reuses the diagrams from our beam types and supports guide.
| Condition | Quick sizing model | Continue in Beam Calculator for |
|---|---|---|
| Simply supported | Pin and roller at the ends | Post loads, partial distributed loads or load positions |
| Cantilever | Fixed left end; free right end | Tip loads, moments or a propped cantilever |
| Fixed beam | Rotation restrained at both ends | Spring restraints or a different support model |
| Overhanging | One right overhang; enter backspan and projection | Overhangs at both ends or different load extents |
| Continuous | Two equal spans, both fully loaded | Unequal spans, more supports and patterned live loads |
Deflection limits use each support-to-support span or the physical cantilever/overhang projection. A continuous member can develop negative moment over a support; bracing must restrain the relevant compression flange. A floor attachment on one flange does not automatically establish all the assumed restraint.
For floor beams, lintels, roof framing or projecting beams: use the quick model only when its loads and restraints match. Continue with your current model in Beam Calculator to represent the actual application, including concentrated loads, roof load cases and combinations. You keep the selected section and entered inputs.
Steel floor beam loads and tributary width
A floor load in psf is a load per area. A beam needs a line load in lb/ft or kip/ft. Multiply each area load by the width of floor delivering load to that beam; calculate dead and live loads separately.
50 psf × 10 ft = 500 lb/ft = 0.5 kip/ft
100 psf × 10 ft = 1,000 lb/ft = 1.0 kip/ft
For simple, one-way framing supported on two lines, a beam commonly receives half the joist span from each supported side. For example, 8 ft joists on one side and 12 ft joists on the other give 4 + 6 = 10 ft of tributary width. Verify the actual load path; continuous framing or a post above may require a different model.
| Load entry | US customary | Metric |
|---|---|---|
| Area × width | psf × ft ÷ 1,000 = kip/ft | kN/m² × m = kN/m |
| Line load | 1 kip/ft = 1,000 lb/ft | 1 kN/m ≈ 68.52 lb/ft |
| Beam self-weight | Added to dead load separately for every candidate section | |
Dead load includes the permanent supported construction. Live load depends on the use of the supported area. Enter dead load excluding the steel beam itself. These example loads are illustrative inputs, not prescribed floor or roof loads. Snow, wind, uplift and roof-live combinations need a project-specific setup in the full calculator.
LRFD vs ASD: which load combinations are calculated?
Enter unfactored loads for both methods. Selecting LRFD or ASD changes the strength combinations and available member strength. You do not need to factor the entered loads yourself.
| Check | LRFD | ASD |
|---|---|---|
| Bending and shear demand | Check 1.4D, 1.2D + 1.6L and any added LRFD combinations; retain the governing demand | Check D + L and any added ASD combinations |
| Available strength | Resistance factor × nominal strength, φRn | Nominal strength ÷ safety factor, Rn/Ω |
| Total deflection | Service D + L, including beam self-weight | |
| Live-load deflection | Service L only; no dead load or beam self-weight | |
D is total dead load, including candidate self-weight; L is the entered live load. Here, ASD uses D + L because the tool accepts nonnegative full-span gravity loads: it covers the D-only demand as well. These are limited dead/live presets, not every combination required by ASCE 7 or a governing building code.
Adding a project-specific D/L combination
Expand Custom strength combinations under the beam diagram, choose Add combination and enter the D and L factors. Each extra combination is checked alongside the defaults for the selected method; self-weight receives its D factor. LRFD and ASD additions are stored separately. Switching methods does not reinterpret LRFD factors as ASD factors. Service checks remain D + L and L.
For example, an added 1.3D + 1.7L checks 1.3 × (supported dead load + beam self-weight) + 1.7 × live load. This is an input example, not a prescribed combination. Use the main calculator to replace defaults, edit service combinations or include other cases.
What changes when you switch from LRFD to ASD?
Keep the same physical beam and unfactored loads, select the other method beside Calculate sizes, then recalculate. Strength utilization can change; elastic deflection of the same section does not. A different section may be selected, which can change the reported deflection and self-weight.
For the continuously braced W21×44 example below, LRFD bending demand is 253.44 kip·ft against 357.75 kip·ft available. ASD demand is 173.70 kip·ft against 238.02 kip·ft available. Both methods still give about 1.151 in total deflection. Use the method specified for the project; LRFD and ASD results are not a single-factor conversion.
A reproducible comparison
Steel beam sizing example for a 30 ft span
Assumptions: simply supported; 0.5 kip/ft dead plus 1.0 kip/ft live load; A992 steel; LRFD; continuously braced compression flange; L/240 total and L/360 live deflection. Self-weight is added for each section.
For W21×44, dead load becomes 0.500 + 0.044 = 0.544 kip/ft. The governing LRFD uniform load is 1.2(0.544) + 1.6(1.0) = 2.2528 kip/ft. The maximum moment is wL²/8 = 253.44 kip·ft.
| W-shape | Depth, in | lb/ft | Bending | Shear | Total defl. | Live defl. |
|---|---|---|---|---|---|---|
| W21×44 | 20.70 | 44 | 70.8% | 15.5% | 76.7% | 74.5% |
| W18×46 | 18.10 | 46 | 74.6% | 17.3% | 91.0% | 88.3% |
| W16×50 | 16.30 | 50 | 73.7% | 18.2% | 98.5% | 95.4% |
Which size fits an 18 inch depth limit?
W21×44 is the lightest of these three, but it is 20.70 in deep. W18×46 is 18.10 in deep, so it also exceeds an 18.00 in clearance. W16×50 fits at 16.30 in, but uses 98.5% of the total-deflection allowance. The smallest depth and lowest weight are different objectives.
Both shortcuts retain the stated 30 ft span and loads and require a fresh search. Follow the complete AISC LRFD and ASD hand calculations →
Steel beam span tables: 20 ft, 25 ft and 30 ft
A span alone cannot determine a steel beam size. A useful span table must state the load, section, restraint and deflection criteria. The table below keeps W21×44 and the worked example’s loads and continuous bracing fixed to show what changes with span.
| Span | LRFD moment kip·ft | Total defl. in | L/240 limit in | Search this case |
|---|---|---|---|---|
| 20 ft | 112.64 | 0.227 | 1.00 | |
| 25 ft | 176.00 | 0.555 | 1.25 | |
| 30 ft | 253.44 | 1.151 | 1.50 |
For the same section and line load, bending moment increases with span squared and bending deflection with span to the fourth power. Doubling span produces four times the moment and sixteen times the deflection. This is why a beam-depth rule of thumb is only a starting point.
Compare your supported loads and restraint before using any steel beam span chart. These formulas apply to a simply supported beam. Choose the actual support condition above, or model custom supports in the full calculator.
I-beam sizes, W-beam dimensions and weight
Use the labeled catalog dimensions.
What does W21×44 mean?
W identifies a wide-flange shape. The first number is its nominal depth in inches; the second is weight in lb/ft. W21×44 has an actual depth of 20.70 in and weighs 44 lb/ft.
- d / bf · overall depth / flange width
- Actual dimensions used by the size filters.
- tw / tf · web / flange thickness
- Dimensions used in slenderness and strength checks.
- Ix / Zx · stiffness / plastic section modulus
- Ix enters elastic bending deflection. Zx enters plastic bending strength where the applicable conditions are satisfied.
“I-beam” describes the general shape; W, S and M are distinct AISC shape families. W, S, M and HP sections, C and MC channels, rectangular, square and round HSS, and pipe each have their own search. Metric input units do not change the library to European IPE/HE or UK UB sections. Browse the steel beam sizes database for other catalogs, or use the section properties calculator to explore cross-section geometry.
Steel beam strength and deflection checks
Every selected check must be at or below 100%. “Governing” means the largest demand-to-capacity or deflection-to-limit ratio. Passing bending alone is insufficient.
| Check | Simply supported UDL formula | What the calculator compares |
|---|---|---|
| Bending | Mmax = wL²/8 | Governing strength demand against available AISC flexural strength |
| Shear | Vmax = wL/2 | Support-end shear against available web shear strength |
| Total deflection | δmax = 5wL⁴/(384EIx) | Service D + L deflection against the total limit |
| Live deflection | Same formula using L-load only | Live-only deflection against its separate limit |
In the formulas, w is line load, L is beam span, E is elastic modulus and Ix is major-axis second moment of area. Here E = 29,000 ksi, with equivalent metric units. Keep units consistent; see the beam deflection formulas.
L/240 vs L/360 deflection limits
At 30 ft (360 in), L/240 permits 1.50 in and L/360 permits 1.00 in. A larger denominator means a stricter limit. The defaults are example criteria, not universal AISC limits; choose limits for the supported finishes, use and project requirements.
Why bracing and section compactness matter
Lateral-torsional buckling can reduce bending strength when the compression flange can move sideways and the member can twist. Enter effective interior brace positions, not extra vertical supports. This tool assumes restrained ends for discrete bracing and uses Cb = 1.0.
A doubly symmetric W-shape is not automatically compact. Flange and web slenderness and steel grade determine the applicable local-buckling checks. See the worked compactness calculation; the full calculator shows the applicable calculation trail for the selected section.
What should I review when a section fails?
- Total or live deflection governs
- Compare sections with greater Ix, or revise the actual span/loading arrangement. A higher yield-strength grade alone does not reduce elastic deflection when E and geometry are unchanged.
- Bending governs
- Review both section strength and the actual unbraced length. A heavier section or a valid change in restraint can affect the result; do not assume bracing that the structure does not provide.
- No section fits the size limits
- Check actual depth and section-width filters. Clearing a clearance limit reveals alternatives but does not make them fit the project.
How much load can an existing steel I-beam carry?
Load capacity depends on the section, span, restraint, load arrangement and serviceability limits. A catalog moment capacity in kip·ft is not a uniform load rating in lb/ft.
For a simply supported UDL, a bending-only line-load limit follows w = 8M/L², while a deflection limit gives w = 384EIxδ/(5L⁴). Strength and service loads use different combinations. Include self-weight and check shear and buckling before treating a load as allowable.
This sizing tool finds sections for known loads; it does not solve backwards for a maximum allowable load. To assess a known beam, open the Design workspace, select its section, enter the actual loads and restraints, and choose Check current section. A post or other concentrated load needs its actual position in that model.
Design scope and calculation references
The tool uses Optimal Beam’s shared AISC 360-22 design engine and AISC Shapes Database v16.0. It models one uniform section in major-axis bending with downward dead and live loads over the whole member. Five standard support conditions are available; continuous beams have two equal, fully loaded spans. Deflection uses linear-elastic Euler–Bernoulli bending.
W, S, M and HP shapes require a compact web. C and MC channels require a compact flange and web, plus confirmation of channel loading and torsional restraint. For rectangular and square HSS, the engine excludes sections with both a slender flange and a slender web. Round HSS and pipe must fall within the supported diameter-to-wall-thickness range. HP shapes are checked as beams. Axial pile capacity requires a separate design.
Connections, bearing, concentrated-force checks, brace adequacy, torsion, floor vibration, composite action and construction conditions need separate assessment. AISC 360 supplies member-design provisions; project loading and the complete combination set must be established separately.
- AISC 360 specification · Chapters B, F and G; Appendix 6 for restraint. Consult applicable errata.
- AISC design verification and benchmark checks · calculation scope and reference cases.
- W21×44 steel beam design example · formulas, substitutions and LRFD/ASD comparison.
Steel beam sizing questions
What size steel beam do I need for a 20 ft or 30 ft span?
Enter the span, supported loads, flange restraint and project deflection limits. The span comparison above keeps one beam fixed to show the effect of length; it is not a general section recommendation. Load a case and calculate to search for passing sizes under those assumptions.
Is this a free steel I-beam calculator?
Yes. Size I-beams, channels, HSS and pipe as often as you need, with no account. Compare passing sections, check utilization and explore shear, bending moment and deflection diagrams. Sizing uses none of the three guest Design runs in Beam Calculator.
A signed-in Free Explorer account gets a one-time 7-day Design preview with calculation PDFs, starting with the first completed check or search. Individual Design subscriptions and Team Design seats include ongoing access. Compare Design access by plan.
Which loads are used for the shear, moment and deflection diagrams?
The diagrams show the service response to the full-span dead and live loads you enter. Before sizing, shear and moment use applied loads alone. Selecting a section adds its self-weight to dead load and uses its major-axis moment of inertia for deflection. The deflection diagram marks the greatest displacement along the member. For an overhang, the backspan and projection each have their own deflection limit, so a smaller displacement can govern sizing. Strength checks use the displayed LRFD or ASD combinations.
Does changing LRFD to ASD automatically recalculate?
No. Changing the method updates the displayed combinations and clears the previous result. Click Calculate sizes to run the new method. Your span and unfactored dead and live loads stay the same.
Does the calculator include all ASCE 7 load combinations?
No. It checks the displayed dead/live gravity presets: 1.4D and 1.2D + 1.6L for LRFD, or D + L for ASD, with separate service deflection checks. You can add nonnegative D/L strength combinations here. Other load types, patterns, replacement defaults and custom service combinations require the full beam calculator.
Can I see the calculations and download a PDF?
A signed-in Design preview or Design plan includes the selected section’s equations, substitutions, governing combinations and calculation PDF. A free account can start its Design preview from a sizing result and keep the selected section and loads.
Can I use psf or metric loads?
Yes. Area-load entry converts psf × tributary width in feet into kip/ft, or kN/m² × metres into kN/m. Switching units preserves the physical inputs. Metric units still use the US AISC shape catalog and AISC design basis.
Should I include the beam’s own weight in dead load?
No. Enter supported dead load excluding the steel member. The calculator adds each candidate’s own weight to D before applying the selected combinations.
Is the lightest passing section the best choice?
It is the lowest-weight passing result for the stated inputs. Available depth, connection geometry, section availability, vibration, cost and project requirements can favor a different section. Compare actual dimensions and all four checks before selecting.
Can I size HSS, channels, cantilevers or continuous steel beams?
Yes. Choose the section family and support condition independently. Rectangular, square and round HSS use A500 grades, and pipe uses A53 Grade B. For channels, verify loading through the shear center or separately check torsional effects, including self-weight. The continuous preset models two equal, fully loaded spans. For unequal spans or point loads, open your beam in the full calculator.