Steel Beam Sizes / Australia / Universal Columns / 250 UC 89
250 UC 89 Steel Beam Dimensions and Properties
ASNZS Universal columns · v2019.11
Diagram, properties emphasis, and nearby alternatives use the selected unit system.
Section diagram
250 UC 89 dimensions
Not to scale. Dimensions shown for reference.
Section properties
Symbols match the steel section finder. Imperial and metric values are shown side by side.
| Property | Imperial | Metric |
|---|---|---|
| Weight | 59.81 lb/ft | 89.00 kg/m |
| Depth, d | 10.25 in | 260.40 mm |
| Flange width, bf | 10.07 in | 255.90 mm |
| tw | 0.413 in | 10.500 mm |
| tf | 0.681 in | 17.300 mm |
| Area | 17.67 in² | 11,400.00 mm² |
| Ix | 343.56 in⁴ | 143,000,000 mm⁴ |
| Iy | 116.52 in⁴ | 48,500,000 mm⁴ |
| Sx | 67.02 in³ | 1,098,310 mm³ |
| Sy | 23.13 in³ | 379,054.32 mm³ |
| Zx | 75.06 in³ | 1,230,000 mm³ |
| Zy | 35.09 in³ | 575,000.00 mm³ |
| rx | 4.41 in | 112.00 mm |
| ry | 2.57 in | 65.23 mm |
| J | 2.50 in⁴ | 1,040,000 mm⁴ |
| Cw | 2,666.31 in⁶ | 716,000,002,048 mm⁶ |
Alternatives
Useful nearby sections
Same-series weight neighbors, closest Ix, and a nearby depth series when available — with percent change versus 250 UC 89.
Lighter in Universal columns
250 UC 73
- Weight
- 73.0 kg/m (-18%)
- Depth
- 254.0 mm (-2.5%)
- Ix
- 114,000,000 mm⁴ (-20%)
Heavier in Universal columns
310 UC 97
- Weight
- 97.0 kg/m (+9.0%)
- Depth
- 307.8 mm (+18%)
- Ix
- 222,000,000 mm⁴ (+55%)
Closest Iₓ in Universal columns
200 UC 60
- Weight
- 60.0 kg/m (-33%)
- Depth
- 209.6 mm (-20%)
- Ix
- 60,900,000 mm⁴ (-57%)
Source: Australian-Sections.xlsx (Sheets 1-19) · v2019.11 · Methodology